7. Dimensions and Electrical Information
a. The console shall include a universal 100 – 240vac power supply.
b. Total power consumption shall not exceed 250 VA (including
monitors).
c. The console shall be constructed from aluminum and molded
polyurethane.
d. Dimensions:
Width: 58 cm (23”)
Depth: 36 cm (14”)
Height: 11 cm (4.5”)
Weight: 6kg. (13 lb.)
8. Operating Environment
a. The console shall operate in an ambient temperature range from 0° to
40°C (32° to 104°F).
b. Operating location shall be protected from excessive dust and
humidity.
9. Standards compliance
a. The console shall be in compliance with CE standards.
B. System Configuration
1. Service Tools
a. Service Tools shall access basic system configuration. The basic
system configuration shall be protected by a password.
2. System Parameters
a. System defaults shall be operator definable in the system Parameters
menu. The system defaults shall include, but not be limited to, default
memory time, real time clock and date, default Reset fade, number of
Autosave generations retained, and MIDI in/out and MIDI sync
channels.
C. Control Attributes
1. Channel control
a. Channels shall be selected using the numeric keypad, withà, +, -, &,
and Except syntax. Selections may also be possible through pre-
programmed groups, by selection of active channels visible on stage,
or by selection of channels from memories. There shall be a shortcut
to recall the last selection.
b. Intensity levels shall be set using the @ key and assigning an absolute
value on the numeric keypad or using the Dimmer Wheel. There shall
be dedicated keys for Full, On, and Zero intensity assignments. The